Datasheet

WEX3 serirs high efficiency flameproof three-phase asynchronous motors
WEX3_80M1_4_0.55_400_50_IE3_B5_Ex db eb IIBT4 Gb
Electrical data | |
Rated voltage (V) | 400 |
Rated power (kW) | 0.55 |
Service factor | 1 |
Frequency (Hz) | 50 |
Converter opration range (Hz) | Optional |
Poles | 4 |
Start-up Performance | N |
Rated speed (r/min) | 1430 |
Rated current (A) | 1.3 |
Service current (A) | 1.3 |
Locked rotor current times | 6.3 |
Rated torque (N.m) | 3.7 |
Locked rotor torque times | 2.3 |
Breakdown torque times | 2.3 |
Efficiency class | IE3 |
Efficiency 50% Load(%) | 80.3 |
Efficiency 75% Load(%) | 80.6 |
Efficiency 100% Load(%) | 80.8 |
Power factor 50% Load | 0.50 |
Power factor 75% Load | 0.65 |
Power factor 100% Load | 0.75 |
Temperature rating(℃/2h) | Standard |
Mechanical data | |
Noise [ Lw dB(A) ] | 58 |
Noise [ Lp dB(A) ] | 50 |
Moment of inertia (kg·m2) | 0.0024 |
Bearing drive end | 6204-2Z |
Bearing non-drive end | 6204-2Z |
Shaft key | A |
Regreasing device | NA |
Drain holes | NA |
Painting color | FED33303 |
Site conditions | |
Ambient temperature (°C) | -15~40 |
Altitude above sea level (m) | 1000 |
Humidity (%) | 90 |
Standards and specifications | IEC |
General data | |
Frame size | 80M1 |
Mounting | B5 |
Weight (kg) | 40 |
Frame material | Cast iron |
Fan material | Engineering plastics |
Fan cover material | Cold rolled steel |
Pretection degree | IP55 |
Cooling | IC411 |
Vibration level | A |
Insulation class | F |
Duty type | S1 |
Rotation direction | Bidirection |
Terminal box | |
Material of terminal box | HT250 |
Terminal box position | Top |
Cable entry towards | Right |
Cable gland | Optional |
Gland material | Optional |
Gland specification | 1-M25×1.5 |
Cable entry | φ11~φ16 |
Lead wire terminal | M5 |
Special configurations | |
Heating belt | Optional |
Thermal protection device | Optional |
Independent temperature measure terminal box | Optional |
Encoder | NA |
Overspeed switch | NA |
Shaft current proof Device | NA |
Vibrating hole | NA |
Bearing temperature measurement | NA |
Optional |
Explosion protection | |
Explosion-proof label | Ex db eb IIBT4 Gb |
Application area | Zone 1 |
Explosive atmosphere | gas |
TE time | NA |
Explosion-proof self-extinguishing valve | NA |
The data is subject to change without notice. please pay attention to change to the time. Release time:2021-04-15
Seperately driven fan | |
Wire-out mode | |
Lead position | NA |
Cable type (mm2) | NA |
length of main lead wire (m0 | NA |
Terminal of main lead wire (mm) | NA |
Specification of grounding Wire (mm2) | NA |
length of grounding wire (m) | NA |
Terminal of grounding wire (mm) | NA |
Specification of Pipe Joints (mm) | NA |
Quantity of Pipe Joints | NA |
Cable conduit | NA |
The data is subject to change without notice. please pay attention to change to the time. Release time:2021-04-15