Products Database
Datasheet
WEX3 serirs high efficiency flameproof three-phase asynchronous motors
WEX3_80M1_4_0.55_400_50_IE3_B5_Ex db eb IIBT4 Gb
Electrical data
Rated voltage (V) 400
Rated power (kW) 0.55
Service factor 1
Frequency (Hz) 50
Converter opration range (Hz) Optional
Poles 4
Start-up Performance N
Rated speed (r/min) 1430
Rated current (A) 1.3
Service current (A) 1.3
Locked rotor current times 6.3
Rated torque (N.m) 3.7
Locked rotor torque times 2.3
Breakdown torque times 2.3
Efficiency class IE3
Efficiency 50% Load(%) 80.3
Efficiency 75% Load(%) 80.6
Efficiency 100% Load(%) 80.8
Power factor 50% Load 0.50
Power factor 75% Load 0.65
Power factor 100% Load 0.75
Temperature rating(℃/2h) Standard
Mechanical data
Noise [ Lw dB(A) ] 58
Noise [ Lp dB(A) ] 50
Moment of inertia (kg·m2) 0.0024
Bearing drive end 6204-2Z
Bearing non-drive end 6204-2Z
Shaft key A
Regreasing device NA
Drain holes NA
Painting color FED33303
Site conditions
Ambient temperature (°C) -15~40
Altitude above sea level (m) 1000
Humidity (%) 90
Standards and specifications IEC
General data
Frame size 80M1
Mounting B5
Weight (kg) 40
Frame material Cast iron
Fan material Engineering plastics
Fan cover material Cold rolled steel
Pretection degree IP55
Cooling IC411
Vibration level A
Insulation class F
Duty type S1
Rotation direction Bidirection
Terminal box
Material of terminal box HT250
Terminal box position Top
Cable entry towards Right
Cable gland Optional
Gland material Optional
Gland specification 1-M25×1.5
Cable entry φ11~φ16
Lead wire terminal M5
Special configurations
Heating belt Optional
Thermal protection device Optional
Independent temperature measure terminal box Optional
Encoder NA
Overspeed switch NA
Shaft current proof Device NA
Vibrating hole NA
Bearing temperature measurement NA
Winding temperature measurement Optional
Explosion protection
Explosion-proof label Ex db eb IIBT4 Gb
Application area Zone 1
Explosive atmosphere gas
TE time NA
Explosion-proof self-extinguishing valve NA
The data is subject to change without notice. please pay attention to change to the time. Release time:2021-04-15
Seperately driven fan
 
Wire-out mode
Lead position NA
Cable type (mm2) NA
length of main lead wire (m0 NA
Terminal of main lead wire (mm) NA
Specification of grounding Wire (mm2) NA
length of grounding wire (m) NA
Terminal of grounding wire (mm) NA
Specification of Pipe Joints (mm) NA
Quantity of Pipe Joints NA
Cable conduit NA
The data is subject to change without notice. please pay attention to change to the time. Release time:2021-04-15
Print Data sheet Outline drawing Performance curves Product manual Add special requirements
Performance Curves
Special requirements
The following factors should be taken into account in motor selection
Voltage(V)
Frequency(Hz)
Standard motor(VFD)
Mounting type
Operating conditions
Protection grade
Equipment type and moment of inertia of load
Connection mode between the motor and load
Start mode, start frequency, start voltage drop, etc.
Operating mode
Insulation classl
Rotation direction
Wiring box position
Shape of terminal box inlet
Ex Mark
Power supply voltage and frequency for draught fan
Other
Technical data is only available to our registered members. Please login or contact us to create a membership account. No account? Register!
Username
Password
Verify: